Search results for "Automatic frequency"
showing 10 items of 20 documents
Frequency-domain experimental setup for mechatronic and suspension system components
2021
This paper presents a frequency-domain experimental setup for modal analysis of mechatronic and suspension system components. Design, instrumentation and dynamic behavior of the one degree-of-freedom (DOF) system, capable of providing both, periodic and application-specific, excitation forces is described. The excitation is realized by an electromagnetic modal shaker with additional assembly and interface components designed and instrumented for frequency -domain analysis of vertical dynamics. Frequency response functions (FRFs) of the implemented system are experimentally measured and the associated basic model parameters are calculated, correspondingly identified. Accurate fit between the…
Analysis and simulations of the primary frequency control during a system split in continental europe power system
2021
The occurrence of system separations in the power system of Continental Europe has been observed in recent decades as a critical event which might cause power imbalances higher than the reference incident specified per system design, representing an actual challenge for the stability and safe operation of the system. This work presents an analysis and simulations of the primary frequency control in the Continental Europe synchronous area in conditions of system separation. The adopted approach is based on fundamental aspects of the frequency-containment reserve process. The analysis takes an actual event into consideration, which determined the separation of the system in January 2021. The …
Frequency stability in microgrid: control strategies and analysis of BESS aging effects
2016
In order to ensure a thorough analysis, all components placed in a microgrid would have to be considered to guarantee an effective energy management. To this aim, various algorithms are used both to preserve and restore power systems after significant disturbances. However, these models frequently do not evaluate components performance decline with the age and, consequently, they don't consider actual values during microgrid analysis, potentially affecting obtained results. In particular, evaluating energy storage systems aging and their effects has rarely been addressed in prior works. The present article proposes a model to maintain power system/microgrid stability after disturbances usin…
Control circuit design of the L-LC resonant inverter for induction heating
2002
In this article, the frequency variation control strategy for an induction heating L-LC resonant inverter is analyzed. The control consists of three loops, which are analyzed and reduced to their corresponding small-signal block diagrams. From these diagrams, the optimal structure of the compensation network and the design boundaries for first order closed-loop response are derived. The special case of phase limitation is analyzed because it is unstable in open-loop operation. Finally the implementation of the control circuit is described and experimental results are shown.
Cascaded PD-PI controller for active power frequency control of two-area multi-units power system
2016
In interconnected multi-area power system; the real power generation within each area has to be managed through active power frequency control considering scheduled power exchange. In this work, two different controllers, namely cascaded PD-PI and conventional PID controller are considered for analyzing the dynamic response of the two area interconnected power system. Area-1 consists of two reheat type thermal generating power plant units and area-2 comprises of two non-reheat type thermal power plant units. The controller gains of PD-PI and PID controllers are efficiently tuned by ‘Teaching Learning based Optimization Technique’. In area-1, 1% step load disturbance is applied for analyzing…
Review on photovoltaic based active generator
2015
An active generator has the capacity to support frequency control and instantaneous power balance. The grid operator adjusts the power dispatch of generators according to power demand fluctuations. Photovoltaic (PV) based active generators can be used as load following generators in the same manner as other power dispatch generators. This new type of distribution system, based on active generator(s), needs new innovative management and operation strategies for increasing the penetration of intermittent renewable energy systems. The considered PV based active generator has three units, i.e., PV array, battery storage and super capacitor. In this review paper, the management and operation app…
A parametric study on unbalanced three phase islanded microgrids with inverter interfaced units
2013
In this paper, the solution of the power flow for unbalanced three phase microgrids systems is proposed. The study aims at the integration of inverter interfaced units using the control law used for primary voltage and frequency regulation, so as to take into account possible small variations of these parameters to account for sudden load changes. The proposed study deals with unbalanced systems which is the typical case of small distribution systems and shows how the power losses term varies as the regulators parameters vary as well, thus showing that these are sensitive parameters that could have an important role in optimal management of such systems.
Green Data Centres providing ancillary services to power grid
2015
This work investigates the possibility for a Data Centre to provide services to the Grid. In particular, the paper simulates a sudden shift of frequency because of a power decrease and estimates how a real-life Data Centre can contribute the secondary frequency regulation.
Primary Frequency Control in the Power System of Continental Europe including the Dynamics of the HVDC Link France-Great Britain
2020
The paper presents a study of primary frequency control within the power system of Continental Europe (CE) including the dynamics of the high voltage direct current (HVDC) link between France and Great Britain (GB). The large-scale dynamic model of the CE system originally provided by ENTSO-E is extended with a more detailed representation of the whole HVDC interconnection. The dynamics of the GB synchronous area is also considered in the analysis, implementing a system equivalent suitable for primary frequency control studies. The opportunity of frequency containment reserve exchange between the two areas through the link is also investigated, considering supplementary frequency controls w…
A discrete pulse group control-based series resonant inverter with complete ZCS-assisted inductors for consumer high frequency IH application
2017
This paper presents a pulse density modulated (PDM) voltage source high frequency series load resonant soft switching inverter (SRI) for the HF induction heated fixing roller in the energy saving copy and printing machines. The proposed simple and high efficiency SRI based on PDM control operation can achieve complete zero current soft switching for wide output power regulation ranges. In this work, its transient and steady-state operating principle are described and analyzed on the basis of high frequency PDM. The operating performances as power conversion efficiency, power losses analysis and temperature rising characteristics of this SRI are demonstrated and discussed through experimenta…